PART NUMBER: DWA218495
Fuel Type .......................................... LPG Liquid/Vapor
Inlet Pressure
Maximum ............................... 312 psi (21.51 Bar)
Minimum Pressure ................ 30 psi (207 kPa)
Nominal Outlet Pressure
Standard (blue spring) .......... -1.5” w.c. (-0.37 kPa)
HP/kW .............................................. 100 hp (75 kW)
Operating Temperature Range ......... -40°F to +250°F (-40°C to +121°C)
Fuel Filtration Required ..................... 40 micron
Heating Chamber Source .................. Required for liquid LPG
Mounting Position .............................. Vertical recommended. Horizontal position can be used
when fuel contamination can be controlled with HD-5 or
HD-10 specified LPG fuel.
Applications ....................................... Mobile, stationary, industrial and automotive
Certification ....................................... UL (AU1502) Inquire for specific ECE approval